Fire alarm:LS-30F Fire Alarm Panel
Addressable Fire Alarm Panel
Input Power: 12 DC/300mA unregulated or 15VDC/>300mA regulated.
Standby Current: 50mA.
RF : (Follows local regulations, other frequencies as requested)
Frequency: 426, 433 and 868MHz
Data Modulation: Narrow-band FM or OOK.
Power: less than 10mW.
Range: about 200ft or more @open field, 25℃.
Receiver Type: super heterodyne.
RF Security Code: 16,777,216 combinations with check sum for each type of sensors.
More than 4 billion combinations in total.
Communication Link: PSTN (Telephone)/ GSM/ Ethernet
Telephone Dialing: Pulse/Tone selectable.
Preset Telephone Number: 10 phone numbers, one pager, 5 GSM/SMS numbers, 2 CMS data links (both with PSTN and GSM numbers).
Voice Recording: 120 seconds in total.
Emergency announcement in 6 segments, 13 seconds for common segment, 4 seconds each for Panic, Burglar, Fire, Medical, Special and Latchkey/ Power segments.
Event Log: max. 512 records.
Display: 3 LEDs, 2x16 LCD panel with blue color backlight.
Sensor Zones: total 288 zones. (Burglar zones x 128, Fire zones x 64, Controller zones x 32,
Medical zones x 32, Special sensor zones x 32)
Memory Back-up Time: Min. 3 months after power break.
Battery Back Up Operation Time: about 16-28 hours. (depends on back up battery type, only for the Base Unit)
Password: 14 passwords each with max. 8 digits.
Wire Sensor Inputs: 3 sensor inputs, each can be assigned as panic, burglar, fire, medical or tamper.
Alarm Out: 230V AC /3A rate relay contacts or 12-15V DC output selectable.
Delay Activation Time: 0- 255 seconds programmable.
Digital Interfaces COM1: UART (0-5V, 9600/ 8 bits/no parity/1stop bit)
For RS-232 Adaptor, USB Adaptor, 10M/100M Ethernet Adaptor and Dial up Modem
Digital Interface COM2: (for GSM module and X-10 switches control)
For GSM module, UART (0-5V, 9600/ 8 bits/no parity/1stop bit).
For X-10 control, X-10 protocol for the control of 16 units X-10 switches.
Remote Display Memory: 30 characters/set, total 10 sets.
Internal Siren: 110dB at 30cm distance.
CMS protocol: Contact ID with 2-way voice.
Clock Accuracy: within 5 seconds daily.
Telephone Line Cut Detection Voltage: 20V+/- 4V. (this function may not be used in some countries.)
Operation Temp.: -10℃~40℃.
Storage Temp.: -20℃~55℃.
Humidity: 10-95%RH.
Size: 248x180x52 mm.
Weight: about 950 g.